Display Data Channel Testing in a 50 m HDMI Link

When a long HDMI link shows a black screen, flickering, or handshake failures, the high-speed video path may not be the cause. Examining the Display Data Channel waveforms can help narrow down the problem.

This Smartavlink test compares a 50 m baseline with a 51 m link using an S105 adapter at the TX, or source, end. It looks beyond whether a picture appears to examine the clock and data signals themselves.

S105 adapter sample; AI-enhanced from the supplied product photograph.

The key results: SCL positive overshoot fell from 10.0% to 4.5%, and the reported SCL and SDA amplitudes both reached 4.40 V. The record describes complete pulses with no observed stuck bus during the capture.

Two limits matter when interpreting these results. The SDA minimum reached −2.20 V and needs further checking. The configurations also differ in length, so this comparison alone does not isolate the adapter’s effect.

Why a video link can still have handshake problems

A long HDMI link carries more than high-speed video. The source and display must also exchange display-capability information and complete content-protection communication. The Display Data Channel is one of the key paths for these exchanges.

It uses SCL, the Serial Clock line, and SDA, the Serial Data line. The source reads Extended Display Identification Data (EDID) to learn the display’s capabilities. It also uses this path for High-bandwidth Digital Content Protection (HDCP) communication.

Hot Plug Detect (HPD) is a separate status signal. Changes in connection status can trigger another EDID read or link initialization. Analog Devices’ HDMI interface explanation describes these functions.

Even when the video path has enough bandwidth, inadequate control-signal levels or timing can disrupt the handshake. Symptoms may include no picture, incorrect resolution detection, failure to establish HDR, or inconsistent recovery after a restart.

What the S105 test was designed to find out

The test asks a practical question: how do the SCL and SDA waveforms change when S105 is used in an approximately 50 m HDMI link? The comparison examines signal levels, amplitude, overshoot, undershoot, and pulse continuity.

Configuration

The main comparison is between A and B. S106 data from the receiving end appears only as a reference in the source record; it is not part of the S105 conclusion. A repeat test at the same length would provide a stronger comparison.

Measurement settings

SCL: Channel 1, shown in blue. SDA: Channel 2, shown in yellow.

Vertical scale: 5.000 V/div on both channels. Timebase: 20.0 µs/div.

Trigger: Channel 1 rising edge, with a 600 mV trigger level.

Using the same scales helps compare waveform shapes. Probe settings, grounding, and measurement points must also be consistent.

What the waveform data tells us

Original same-scale comparison. Top SCL; bottom SDA. Left (A) 50 m without S105. Right (B) 51 m with S105 at the source end.

SCL showed a more distinct high-level region

In the baseline capture, the SCL upper region is sloped rather than flat. With S105 in configuration B, it appears flatter and more distinct. SCL High increased from 3.60 V to 4.00 V; amplitude increased from 4.00 V to 4.40 V.

A clearer high-level region can help a receiver distinguish logic states. Whether it improves the receiver’s logic margin depends on its thresholds and timing requirements.

SDA showed a steeper rising edge

The baseline SDA transition has a rounded shape resembling an RC charging curve, with a narrower high-level region. Configuration B shows a steeper rising transition. High increased from 3.00 V to 3.20 V; amplitude increased from 4.20 V to 4.40 V.

The shape is relevant to EDID and HDCP communication, where the signal must reach a valid level at the required time. The captures do not supply a numerical rise-time or timing-margin measurement.

Positive overshoot decreased but the negative peak needs follow-up

SCL positive overshoot fell from 10.0% to 4.5%, a reduction of 5.5 percentage points. SDA positive overshoot also fell, from 14.3% to 9.1%.

Three readings from the original table. The lower positive overshoot and more negative SDA minimum must both be considered. A and B are different-length configurations.

SDA Min moved in the other direction: −1.60 V to −2.20 V. Its signed undershoot changed from −9.5% to −22.7%. This result should remain visible alongside the higher signal levels.

Repeat the measurement with a finer vertical range, a short ground spring, and the same probe location. Check the reference ground, attenuation, and input coupling as well. This can help distinguish a real link excursion from an effect of the measurement setup.

Probe grounding can distort fast transitions, as explained in Analog Devices’ short-ground-lead guidance. The negative peak should be checked rather than assumed to be an artifact.

Reported metric

All voltage readings are in volts. Ampl = High − Low, while peak-to-peak voltage is Max − Min. Positive overshoot = (Max − High) / Ampl × 100%; signed undershoot = (Min − Low) / Ampl × 100%.

Did communication remain continuous

A better-looking waveform is not the only goal. The test also examines whether communication activity continues during the captured interval.

Original baseline capture 50 m without S105. SCL is the blue trace; SDA is the yellow trace.

The source record reports an SCL frequency of 71.43 kHz, a period of 14.00 µs, an SDA duty cycle of 17.28%, and a communication burst lasting 3.64 ms. These are observations from the reported capture, not fixed values for all Display Data Channel transactions.

Original capture 51 m with S105 at the source end. The waveform photograph has not been retouched.

The record describes complete SCL and SDA pulses with no observed loss or stuck bus. That supports continuity within the captured interval. Confirming successful EDID reads and HDCP authentication still requires transaction decoding or equipment-level checks.

The results therefore apply to this recorded link and equipment combination. Deployment still needs end-to-end testing at the intended length and operating modes.

The practical engineering value of S105 evaluation

Assessing the electrical margin of the control path

Longer electrical paths can add capacitance and slow rising edges. The higher levels and amplitudes in this comparison provide a reason to evaluate source-end conditioning. Actual receiver margin needs to be checked against its limits. NXP’s I2C-bus specification explains the relationship between bus capacitance, pull-up resistance, and rise time.

Making handshake troubleshooting more focused

When the video path appears sound but EDID reads or HDCP authentication are inconsistent, Display Data Channel waveforms provide a concrete diagnostic reference. They help direct the next measurement instead of relying only on repeated equipment substitutions.

Checking whether the complete system has enough margin

A link that produces a picture in the lab may behave differently after connectors, adapters, warmer equipment, and repeated cold starts are introduced. Evaluating signal shape helps determine whether the final system has sufficient operating margin.

Avoiding unnecessary intermediate devices

If a source-end adapter solves the specific control-path problem, it may avoid the need for several temporary repeaters or power accessories. This can simplify wiring and troubleshooting. Whether any device can be removed must be confirmed on the complete link.

What to verify before deployment

Use the final equipment combination. Include the actual source, matrix switcher, distribution amplifier, long cable or active optical cable, and display or capture device.

Test the required operating formats. Cover resolution, refresh rate, color depth, HDR, audio, and HDCP. A static desktop picture is only one condition.

Exercise power and handshake recovery. Include cold starts, hot plugging, different source/display power-up orders, source restarts, and input switching.

Measure at repeatable points. Check SCL and SDA levels, rising edges, overshoot, undershoot, and burst continuity. Keep probes, grounding, and acquisition settings consistent.

Record the limits as well as passes. Save equipment models, firmware, cable length, adapter location, ambient temperature, and the conditions that reproduce a failure.

For route planning, see Smartavlink’s fiber optic HDMI cable installation checklist.

When S105 is worth considering

Consider checking Display Data Channel signal integrity and evaluating S105 at the source end when the main video path has no confirmed fault, but the system shows these symptoms:

  • The display intermittently reports no signal and recovers after reconnection.
  • EDID reads are inconsistent, or resolution and HDR capabilities are detected incorrectly.
  • HDCP authentication fails occasionally, or switching sources produces a black screen.
  • A direct long-cable connection works, but adding a matrix switcher, wall plate, or adapter reduces stability.
  • Cold and warm starts behave differently, or the system needs several restarts before a picture appears.
  • These symptoms guide investigation; they do not prove that S105 is the right solution for every system.

Reliability needs more than a working picture

Long HDMI projects should not be judged only by whether the display lights up. The Display Data Channel carries key EDID and HDCP exchanges. Its levels, edges, and transient behavior matter to a reliable handshake.

In the recorded 51 m configuration with S105 at the source end, SCL and SDA High levels and amplitudes increased. SCL positive overshoot fell, and the record describes continuous pulses. The more negative SDA peak remains a follow-up item.

This is the value of measurement: identifying useful changes while keeping the limits visible. Before handover, use the final equipment, final cable length, and required operating formats for end-to-end validation.

Need help evaluating your long HDMI link? Share the source and display models, target formats, cable length, intermediate devices, and symptoms with Smartavlink. The team can use this information to discuss test points, source-end S105 evaluation, and a project validation checklist.

Test scope: the supplied record covers a prototype and the configurations tested on November 11, 2026. The original note estimates about 0.16 V vertical resolution at 5 V/div; this is not an accuracy specification. Recheck the 0.20 V level difference at a suitable finer range. These observations do not replace project compatibility testing or site acceptance.

Technical terms explained

Display Data Channel. The HDMI control path for display-capability and related exchanges, including HDCP communication.

I2C, SCL, and SDA. I2C means Inter-Integrated Circuit. SCL is Serial Clock; SDA is Serial Data. Together they form the two-wire bus discussed here.

EDID. Extended Display Identification Data. Display information that lists supported formats. See Analog Devices’ explanation.

HDCP. High-bandwidth Digital Content Protection. A content-protection system that includes device authentication.

HPD. Hot Plug Detect. A separate HDMI connection-status signal.

TX and RX. The transmitting/source end and receiving/display end. S105 was at TX in this record.

AOC. Active Optical Cable. Active electronics convert high-speed electrical signals to optical signals and back. Other functions may still use conductors.

HDR. High Dynamic Range. A video feature supporting a wider brightness range; the intended format needs compatible equipment throughout the link.

High, Low, and Ampl. High and Low are measured waveform levels. Ampl = High − Low. Max and Min are the recorded extremes.

Overshoot, undershoot, and ringing. Excursions above High, below Low, and oscillation around a transition, respectively.

Rise time and pull-up circuitry. Rise time describes the low-to-high transition. Pull-up circuitry restores a released line toward its high level; resistance and capacitance affect its speed.

Voltage and timing margins. The clearance between actual signals and the receiver’s electrical or timing limits. Amplitude alone does not quantify either.

V per division and microseconds per division. V/div and µs/div are oscilloscope scales. They are not accuracy specifications. A microsecond is one millionth of a second.

Frequency and period. Frequency counts cycles per second; kHz means thousands of cycles per second. Period is the time for one cycle. A millisecond is one thousandth of a second.

Duty cycle and burst. Duty cycle is the fraction of an interval spent high. A burst is a group of communication activity within an interval.

Stuck bus and acknowledgment. A stuck bus cannot resume normal transfers, often because a line remains low. An acknowledgment is a protocol response to a transferred byte.

PCB. Printed Circuit Board. The board that supports components and conductive connections; the S105 sample has an exposed board.